Panels

7.2 Panel

product-72

  • Description
  • 7.2 Properties
  • Allowable Uniform Loads In Pounds Per Square Foot

When your design calls for a commercial or industrial exposed fastener panel, the 7.2 Panel is an ideal choice. This panel offers versatility and functionality for roofs and walls. The symmetrical rib 7.2 Panel offers excellent spanning and cantilever capabilities, making it an excellent choice for carports and walkway canopies.

Gauge
  • 24 gauge (standard)
  • 29, 26, 22 gauge (optional)

 

Dimensions
  • 36″ wide and 1-1/2″ Rib Height

 

Finish
  • Galvalume Plus®
  • Signature® 200
  • Signature® 300
Limitations
  • Recommended for roof slopes of ½:12.

 

Usage
  • When your design calls for a commercial or industrial exposed fastener panel, the 7.2 Panel is an ideal choice. This panel offers versatility and functionality for roofs and walls. The symmetrical rib 7.2 Panel offers excellent spanning and cantilever capabilities, making it an excellent choice for carports and walkway canopies.

7.2 – Section Properties

  NEGATIVE BENDING POSITIVE BENDING
Panel Gauge FY (KSI) WEIGHT (PSF) Ixe (IN.4/FT.) Sxe (IN.3/FT.) Maxo (KIP-IN.) Ixe (IN.4/FT.) Sxe (IN.3/FT.) Maxo (KIP-IN.)
29 60* 0.66 0.0426 0.0419 1.5073 0.0426 0.0419 1.5073
26 60* 0.86 0.0645 0.0682 2.4505 0.0645 0.0682 2.4505
24 50 1.06 0.0918 0.1039 3.1125 0.0918 0.1039 3.1125
22 50 1.36 0.1252 0.1462 4.3718 0.1252 0.1462 4.3718

*Fy is 80-ksi in accordance with the 2007 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members – A2.3.2.

Properties Notes:
  1. All calculations for the properties of 7.2 panels are calculated in accordance with the 2001 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members.
  2. Ixe is for deflection determination.
  3. Sxe is for bending.
  4. Maxo is allowable bending moment.
  5. All values are for one foot of panel width.

Allowable Uniform Loads In Pounds Per Square Foot

drawing_7-2

29 Gauge (Fy = 60 Ksi)
SPAN TYPE LOAD TYPE SPAN IN FEET
3.0 4.0 5.0 6.0 7.0 8.0 9.0
SINGLE NEGATIVE WIND LOAD 111.6 62.8 40.2 27.9 20.5 15.7 12.4
LIVE LOAD /
DEFLECTION
82.5 58.2 29.8 17.2 10.9 7.3 5.1
2-SPAN NEGATIVE WIND LOAD 111.6 62.8 40.2 27.9 20.5 15.7 12.4
LIVE LOAD /
DEFLECTION
72.2 56.1 37.3 26.5 19.7 15.2 12.1
3-SPAN NEGATIVE WIND LOAD 139.5 78.5 50.2 34.9 25.6 19.6 15.5
LIVE LOAD /
DEFLECTION
86.6 64.9 45.3 32.4 20.5 13.7 9.6
4-SPAN NEGATIVE WIND LOAD 130.3 73.3 46.9 32.6 23.9 18.3 14.5
LIVE LOAD /
DEFLECTION
83.3 62.5 42.7 30.5 21.7 14.6 10.2
26 Gauge (Fy = 60 Ksi )
SPAN TYPE LOAD TYPE SPAN IN FEET
3.0 4.0 5.0 6.0 7.0 8.0 9.0
SINGLE NEGATIVE WIND LOAD 181.6 102.1 65.4 45.4 33.4 25.5 20.2
LIVE LOAD /
DEFLECTION
153.7 88.1 45.1 26.1 16.4 11.0 7.7
2-SPAN NEGATIVE WIND LOAD 181.6 102.1 65.4 45.4 33.4 25.5 20.2
LIVE LOAD /
DEFLECTION
129.7 95.8 62.7 44.1 32.6 25.1 18.6
3-SPAN NEGATIVE WIND LOAD 227.0 127.7 81.7 56.7 41.7 31.9 25.2
LIVE LOAD /
DEFLECTION
147.4 110.5 77.0 49.3 31.0 20.8 14.6
4-SPAN NEGATIVE WIND LOAD 211.9 119.2 76.3 53.0 38.9 29.8 23.5
LIVE LOAD /
DEFLECTION
141.8 106.4 72.3 51.0 32.9 22.1 15.5
24 Gauge (Fy = 50 Ksi )
SPAN TYPE LOAD TYPE SPAN IN FEET
3.0 4.0 5.0 6.0 7.0 8.0 9.0
SINGLE NEGATIVE WIND LOAD 230.5 129.7 83.0 57.6 42.3 32.4 25.6
LIVE LOAD /
DEFLECTION
205.0 125.4 64.2 37.1 23.4 15.7 11.0
2-SPAN NEGATIVE WIND LOAD 230.5 129.7 83.0 57.6 42.3 32.4 25.6
LIVE LOAD /
DEFLECTION
163.1 122.3 81.4 56.8 41.9 32.2 25.5
3-SPAN NEGATIVE WIND LOAD 288.2 162.1 103.7 72.0 52.9 40.5 32.0
LIVE LOAD /
DEFLECTION
185.4 139.0 100.9 70.1 44.1 29.6 20.8
4-SPAN NEGATIVE WIND LOAD 269.1 151.3 96.9 67.3 49.4 37.8 29.9
LIVE LOAD /
DEFLECTION
178.4 133.8 94.4 66.1 46.9 31.4 22.0
22 Gauge (Fy = 50 Ksi )
SPAN TYPE LOAD TYPE SPAN IN FEET
3.0 4.0 5.0 6.0 7.0 8.0 9.0
SINGLE NEGATIVE WIND LOAD 324.2 182.4 116.7 81.1 59.6 45.6 36.0
LIVE LOAD /
DEFLECTION
324.2 171.0 87.5 50.7 31.9 21.4 15.0
2-SPAN NEGATIVE WIND LOAD 324.2 182.4 116.7 81.1 59.6 45.6 36.0
LIVE LOAD /
DEFLECTION
264.5 176.3 114.2 79.8 58.9 45.2 35.8
3-SPAN NEGATIVE WIND LOAD 405.3 228.0 145.9 101.3 74.4 57.0 45.0
LIVE LOAD /
DEFLECTION
300.5 217.3 141.4 95.6 60.2 40.3 28.3
4-SPAN NEGATIVE WIND LOAD 378.4 212.9 136.2 94.6 69.5 53.2 42.0
LIVE LOAD /
DEFLECTION
289.2 203.9 132.5 92.8 63.9 42.8 30.1

 

Allowable Uniform Loads Notes:
  1. Allowable loads are based on uniform span lengths and Fy = 50 and 60-ksi.
  2. LIVE LOAD is limited by bending, shear, combined shear & bending and web crippling.
  3. NEGATIVE WIND LOAD does not contain a 33.333% increase and does not consider fastener pullout or pullover.
  4. Above loads consider a maximum deflection ratio of L/180.
  5. The weight of the panel has not been deducted from the allowable loads.
  6. The use of any accessories other than those provided by the manufacturer may damage panels, void all warranties and will void all engineering data.
  7. This material is subject to change without notice. Please contact Robertson for most current data.

The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

EFFECTIVE JANUARY, 2014 SUBJECT TO CHANGE WITHOUT NOTICE

  • 7.2 is a registered trademark of the NCI Group, Inc.
  • Galvalume Plus® is a registered trademark of BIEC International, Inc.
  • Signature® is a registered trademark of the NCI Group, Inc.