Panels

NuWall®

product-nuwall

  • Description
  • NuWall Properties

The NuWall® wall panel can be used for either new or retrofit construction. This concealed fastened system creates a clean, uninterrupted wall on a building. The NuWall® system is based on a 12-inch module. This means that when using NuWall® over existing metal panels, the existing panel ribs must be 6 inches or 12 inches on center.

Gauge
  • 24 gauge (standard)
  • 22 gauge (optional)

 

Length
  • Max= 40′-0″, contact Robertson for longer panels.

 

Dimensions
  • 12″ wide X 2 ½” high

 

Usage
  • For retrofit construction, a 2″ thick layer of Blanket Insulation may be added between existing panel and the NuWall® panels.
Finish
  • Galvalume Plus®
  • Signature® 200
  • Signature® 300

12″ NuWall® 22 Gauge – Negative Design Loads

drawing_nuwall

22 GAUGE
SPAN TYPE 2.50 3.00 3.50 4.00 5.00 5.50 5.50 6.00 6.50 7.00
1592 LOAD 228.80 211.00 192.00 174.00 157.00 140.40 125.00 110.00 97.00 83.20
DESIGN LOAD 114.40 105.50 96.00 87.00 78.50 70.20 62.50 55.00 48.50 41.60

 

12″ NuWall® 24 Gauge – Negative Design Loads

24 GAUGE
SPAN TYPE 2.50 3.00 3.50 4.00 5.00 5.50 5.50 6.00 6.50 7.00
1592 LOAD 169.52 157.00 145.00 134.00 122.00 110.24 98.00 86.00 74.00 62.40
DESIGN LOAD 84.76 78.50 72.50 67.00 61.00 55.12 49.00 43.00 37.00 31.20

 

12″ NuWall® 26 Gauge – Negative Design Loads

24 GAUGE
SPAN TYPE 2.50 3.00 3.50 4.00 5.00 5.50 5.50 6.00 6.50 7.00
1592 LOAD 176.80 157.00 136.00 117.00 98.00 83.20 72.00 66.00 62.00 57.20
DESIGN LOAD 88.40 78.50 68.00 58.50 49.00 41.60 36.00 33.00 31.00 28.60

 

12″ NuWall® 24 Gauge – Positive Design Loads

24 GAUGE
SPAN TYPE 2.50 3.00 3.50 4.00 5.00 5.50 5.50 6.00 6.50 7.00
1592 LOAD 234.00 225.00 216.00 207.00 198.00 187.20 173.00 158.00 141.00 124.80
DESIGN LOAD 117.00 112.50 108.00 103.50 99.00 93.60 86.50 79.00 70.50 62.40

 

12″ NuWall® 26 Gauge – Positive Design Loads

24 GAUGE
SPAN TYPE 2.50 3.00 3.50 4.00 5.00 5.50 5.50 6.00 6.50 7.00
1592 LOAD 166.40 154.00 142.00 131.00 119.00 109.20 101.00 94.00 89.00 83.20
DESIGN LOAD 83.20 77.00 71.00 65.50 59.50 54.60 50.50 47.00 44.50 41.60

 

Notes:
  1. The above loads were derived from uplift tests done in accordance with ASTM E-1592.
  2. All values are interpolated and/or extrapolated from tests performed at spans of 2′-6″, 5′-0″ and 7′-0″.
  3. Test results are highlighted.
  4. Design Load contains a 2.00 factor of safety.
  5. *** indicates insufficient data.
  6. These values do not consider fastener pullout or pullover, fastener attachment must be designed separately.
  7. This material is subject to change without notice. Please contact Robertson for most current data.