Panels

BattenLok® HS

battenlok2

  • Description
  • Advantages & Attributes
  • BattenLok HS – Properties
  • Allowable Uniform Loads

An attractive feature of the BattenLok® HS panel is the vertical leg sidelap seam that is mechanically seamed with an electric seamer for a weathertight finish. This panel features concealed clips and easy to handle 16″ or 12″ wide panels custom cut to the desired length. BattenLok® HS can be installed directly over purlins or bar joists. It does not require a solid substructure for support. This roof system has several different UL® 90 construction numbers.

Gauge
  • 24 gauge (standard)
  • 22 gauge

 

Length
  • Maximum 40′ (standard), other lengths are available
    as special requests

 

Dimensions
  • 16″ wide and 2″ high (standard)
  • 12″ also available

 

Finish
  • Galvalume Plus®
  • Signature® 200
  • Signature® 300

 

Limitations
  • Recommended for roof slopes of ½:12 or greater. Oil canning
    is not a reason for rejection.

 

Fasteners
  • A choice of concealed panel clips is available for this panel system including UL® rated clips. These clips hold the panel firmly in place without unsightly exposed fasteners. Each floating clip system offers the ability to accommodate thermal movement.

 

Usage
  • This panel is a structural panel that spans up to five feet on purlins, or can be used as an architectural panel over solid deck. This flat panel is designed with striations as an option to minimize oil-canning. It is designed to meet the ever-changing specifications and other industry codes.

Advantages

  1. Insures watertightness and easier erection
  2. Improves erection and enhances watertightness
  3. Minimizes oil canning
  4. Flexible and convenient erection
  5. Creates a trimless eave
  6. Increases weathertightness and improves appearance
  7. Minimizes air infiltration and water penetration and enhances acceptability among specifiers
  8. Better transition to hip, valleys, and roof openings
  9. High energy efficiency system
  10. Allows roof to expand and contract maximizing weathertightness
  11. Provides of varying insulation thickness
  12. 25 year finish warranty
  13. Reduces insurance costs
  14. Helps with oil canning

Attributes

  1. Factory applied mastic inside of female leg of panel is standard
  2. Swaged end laps
  3. Heavier gauges, striation and embossing (optional)
  4. Roof runs without end lap panels may be erected from either direction
  5. Roof to wall transition
  6. 80% less exposed fasteners than traditional side lap panels and all-fasteners are long life
  7. The side lap has been tested for air infiltration and water penetration under ASTM E283 and E331 methods
  8. Vertical Leg
  9. Insulated with thermal blocks
  10. High or low floating clips available
  11. High or low fixed clips available
  12. Panel available in Signature® 300 and Signature® 200 Colors
  13. UL® 90
  14. Panel has striations

BattenLok HS® Panel 16″ – Section Properties

  NEGATIVE BENDING POSITIVE BENDING
Panel
Gauge
FY
(KSI)
WEIGHT
(PSF)
Ixe
(IN.4/FT.)
Sxe
(IN.3/FT.)
Maxo
(KIP-IN.)
Ixe
(IN.4/FT.)
Sxe
(IN.3/FT.)
Maxo
(KIP-IN.)
24 50 1.29 0.0644 0.0578 1.7294 0.1517 0.0926 2.7736
22 50 1.65 0.0902 0.0932 2.4923 0.2033 0.1248 3.7370
Properties Notes:
  1. All calculations for the properties of BattenLok HS® panels are calculated in accordance with the 2001 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members.
  2. Ixe is for deflection determination.
  3. Sxe is for bending.
  4. Maxo is allowable bending moment.
  5. All values are for one foot of panel width.

Allowable Uniform Loads In Pounds Per Square Foot – 16″ Panels
drawing_battenlok1

24 Gauge (Fy = 50 Ksi)
SPAN
TYPE
LOAD
TYPE
SPAN IN FEET
2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGLE LIVE 162.0 135.0 115.7 101.3 90.0 74.0 61.1
2-SPAN LIVE 162.0 128.1 94.1 72.1 56.9 46.1 38.1
3-SPAN LIVE 162.0 135.0 115.7 90.1 71.2 57.6 47.6
4-SPAN LIVE 162.0 135.0 109.8 84.1 66.5 53.8 44.5
22 Gauge (Fy = 50 Ksi )
SPAN
TYPE
LOAD
TYPE
SPAN IN FEET
2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGLE LIVE 233.4 194.5 166.7 145.9 123.0 99.7 82.4
2-SPAN LIVE 233.4 184.6 135.6 103.8 82.1 66.5 54.9
3-SPAN LIVE 233.4 194.5 166.7 129.8 102.6 83.1 68.7
4-SPAN LIVE 233.4 194.5 158.3 121.2 95.8 77.6 64.1

 

Note:

For 12″ panel information please contact Robertson.

Allowable Uniform Loads Notes:
  1. Allowable loads are based on uniform span lengths and Fy = 50 ksi.
  2. LIVE LOAD is limited by bending, shear, combined shear and bending and web crippling.
  3. Allowable loads consider a maximum deflection ratio of L/180.
  4. The weight of the panel has not been deducted from the allowable loads.
  5. THE ALLOWABLE UNIFORM LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT.
  6. Please contact manufacturer or manufacturer’s website for most current allowable wind uplift loads.
  7. The use of any field seaming machine other than that provided by the manufacturer may damage the panels, void all warranties and will void all engineering data.

The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

EFFECTIVE JANUARY, 2014 SUBJECT TO CHANGE WITHOUT NOTICE

  • BattenLok HS® is a registered trademark of the NCI Group, Inc.
  • Galvalume Plus® is a registered trademark of BIEC International, Inc.
  • Signature® is a registered trademark of the NCI Group, Inc.