  • Description
  • Rain Guard Properties
  • Allowable Uniform Loads In Pounds Per Square Foot

Rain-Guard® is an excellent water shedding panel. Rain-Guard® is a roof and wall panel ideal for residential, light commercial, agricultural, canopies and storage building use. The Rain-Guard® panel must be installed over a solid, waterproofed deck when used as a roof panel.

Gauge
  • 29 gauge (standard)
  • 26 gauge (optional)

 

Dimensions
  • 36″ wide
  • 6″ on center rib spacing
  • 15/32″ rib height

 

Finish
  • Galvalume Plus®
  • Signature® 200
Limitations
  • Recommended for roof slopes of 3:12.

 

Usage
  • Rain-Guard® is an excellent water shedding panel. Rain-Guard® is a roof and wall panel ideal for residential, light commercial, agricultural, canopies and storage building use. The Rain-Guard® panel must be installed over a solid, waterproofed deck when used as a roof panel.

Rain Guard® – Section Properties

  NEGATIVE BENDING POSITIVE BENDING
Panel Gauge FY (KSI) WEIGHT (PSF) Ixe (IN.4/FT.) Sxe (IN.3/FT.) Maxo (KIP-IN.) Ixe (IN.4/FT.) Sxe (IN.3/FT.) Maxo (KIP-IN.)
29 60* 0.62 0.0028 0.0134 0.4814 0.0047 0.0126 0.4517
26 60* 0.80 0.0040 0.0192 0.6891 0.0062 0.0163 0.5848

*Fy is 80-ksi reduced to 60-ksi in accordance with the 2001 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members – A2.3.2.

Properties Notes:
  1. All calculations for the properties of Rain Guard panels are calculated in accordance with the 2001 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members.
  2. Ixe is for deflection determination.
  3. Sxe is for bending.
  4. Maxo is allowable bending moment.
  5. All values are for one foot of panel width.

Allowable Uniform Loads In Pounds Per Square Foot

drawing_rainguard

29 Gauge (Fy = 60 Ksi)
SPAN TYPE LOAD TYPE SPAN IN FEET
2.0 2.5 3.0 3.5 4.0 4.5 5.0
SINGLE NEGATIVE WIND LOAD 80.2 51.3 35.7 26.2 20.1 15.8 12.8
LIVE LOAD /
DEFLECTION
51.4 26.3 15.2 9.6 6.4 4.5 3.3
2-SPAN NEGATIVE WIND LOAD 75.3 48.2 33.5 24.6 18.8 14.9 12.0
LIVE LOAD /
DEFLECTION
73.1 47.3 33.0 23.1 15.5 10.9 7.9
3-SPAN NEGATIVE WIND LOAD 94.1 60.2 41.8 30.7 23.5 18.6 15.1
LIVE LOAD /
DEFLECTION
90.2 49.6 28.7 18.1 12.1 8.5 6.2
4-SPAN NEGATIVE WIND LOAD 87.9 56.2 39.1 28.7 22.0 17.4 14.1
LIVE LOAD /
DEFLECTION
84.6 52.7 30.5 19.2 12.9 9.0 6.6
26 Gauge (Fy = 60 Ksi )
SPAN TYPE LOAD TYPE SPAN IN FEET
2.0 2.5 3.0 3.5 4.0 4.5 5.0
SINGLE NEGATIVE WIND LOAD 114.9 73.5 51.0 37.5 28.7 22.7 18.4
LIVE LOAD /
DEFLECTION
67.7 34.7 20.1 12.6 8.5 5.9 4.3
2-SPAN NEGATIVE WIND LOAD 97.5 62.4 43.3 31.8 24.4 19.3 15.6
LIVE LOAD /
DEFLECTION
94.6 61.2 42.7 30.4 20.4 14.3 10.4
3-SPAN NEGATIVE WIND LOAD 121.8 78.0 54.1 39.8 30.5 24.1 19.5
LIVE LOAD /
DEFLECTION
116.8 65.4 37.9 23.9 16.0 11.2 8.2
4-SPAN NEGATIVE WIND LOAD 113.8 72.8 50.6 37.1 28.4 22.5 18.2
LIVE LOAD /
DEFLECTION
109.5 69.5 40.2 25.3 17.0 11.9 8.7

 

Allowable Uniform Loads Notes:
  1. Allowable loads are based on uniform span lengths and Fy = 60 ksi.
  2. LIVE LOAD is limited by bending, shear, combined shear and bending and web crippling.
  3. NEGATIVE WIND LOAD does not contain a 33.333% increase and does not consider fastener pullout or pullover.
  4. Allowable loads consider a maximum deflection ratio of L/180.
  5. The weight of the panel has not been deducted from the allowable loads.
  6. Please contact manufacturer or manufacturer’s website for most current allowable wind uplift loads.
  7. The use of any field seaming machine other than that provided by the manufacturer may damage the panels, void all warranties and will void all engineering data.

The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

EFFECTIVE JANUARY, 2014 SUBJECT TO CHANGE WITHOUT NOTICE

  • Rain-Guard® is a registered trademark of the NCI Group, Inc.
  • Galvalume Plus® is a registered trademark of BIEC International, Inc.
  • Signature® is a registered trademark of the NCI Group, Inc.